CXCapacitive Electromagnetic Flowsensor
Feature
System Example
Applications
Specifications
Model | CX | |||
---|---|---|---|---|
Nominal Diameters Accuracy-Guaranteed Flow-Rate Range |
10 | 15 | 20 | |
0.5 ~ 15 L/min | 2.0 ~ 60 L/min | |||
Displayable Flow-Rate Range | 0.0 ~ 18 L/min | 0.0 ~ 72 L/min | ||
Low-Flow Cut-Off | 0.45 L/min | 1.8 L/min | ||
Repeatability Accuracy | ±2%F.S. (No need of straight piping) | |||
Temperature Characteristics |
Ambient Temperature | ±5%F.S. (Relative error when changing from the standard temperature 25°C to 10°C or 50°C) | ||
Fluid Temperature | ±5%F.S. (Relative error when changing from the standard temperature 25°C to 1°C or 85°C) | |||
Piping Connection | Rc3/8 | Rc1/2 | Rc3/4 | |
Fluid Temperature Range | 0 ~ 85°C | |||
Conductivity Range | 5μS/cm ~ 3mS/cm | |||
Measurable Fluids | Water, water-soluble coolant | |||
Working Pressure | 0 ~ 1 MPa | |||
Pressure Resistance | 2 MPa | |||
Pressure Drop | 0.02 MPa or less | |||
Response Time (63% Response) | 0.25s / 0.5s / 1s / 2s / 5s (Default Value: 1s) | |||
Working Ambient Temperature/Working Ambient Humidity | 0 ~ 50°C / 35 ~ 85%RH (Non-condensing) | |||
LED Display | Main Display: 4 digits and 7 segments (Two-color display in green and red) Sub Display: 6 digits and 11 segments (White) | |||
Main Display | Displays either instantaneous flow-rate or accumulated flow volume | |||
Sub Display | Output mode or input mode, flow direction, arbitrary characters (Selectable) | |||
Display Unit | Instantaneous flow-rate: L/min; Accumulated flow volume: L, kL or ML (Selectable) NPN or PNP transistor output *Please select when ordering. |
|||
Switch Output | Maximum Load Voltage/Current | 30 VDC / 50 mA | ||
Output Modes | Level judgment mode/ Window judgment mode/ Trip accumulated flow volume output mode/ Accumulated flow volume pulse output mode/ Alarm output mode (Selectable) (Accumulated flow volume pulse output mode: Nominal Diameter 10: Pulse unit: 0.01 L/P, ON-time: 10 ± 5 ms ; Nominal Diameter 15 and 20: Pulse unit 0.1 L/P, ON-time: 50 ± 5 ms) |
|||
Analog Output *1 |
Voltage/ Current | 1 to 5 V DC load impedance: 50 kΩ or higher/4 to 20 mA load impedance: 500 Ω or less * Please select when ordering. |
||
Switch Input *1 |
Input Time | 20 ms or longer | ||
Short-Circuit Current | Approximately 2 mA | |||
Protection Class | IP65 (When using the body-connection connector cable) | |||
Current Consumption | 65 mA or less | |||
Power Source | 24 VDC ± 10% P-P Ripple within ± 10% | |||
Installation Position | Free | |||
Weight | Approx.460g | Approx.490g | Approx520g | |
Wetted-Parts Materials | PPS / FKM / Bronze (CAC804) | |||
Accessory | Body-connection connector cable: 3 m | |||
Optional Parts | Installation bracket |
Note 1. Please read and understand the product specifications before using the product.
Note 2. In case of consideration to arrange plural pieces of the products by the side of a flow rate type filling apparatus in Japan, please refer to Japanese Patent No. 3916032 before deciding to install them.
*1 Please select either analog output or switch input.
LOOKING FOR DISTRIBUTORS
PDF Download
Specifications may vary by country, about which please confirm at the time of inquiry. |
Download Catalog
・Specifications are subject to change without notice.
・Product Warranties
-
- SU
- Electromagnetic Water Meter
-
- SY
- Electromagnetic Water Meters
-
- SD15S
- Residential Water Meter
-
- TR-Ⅳ
- Portable Water Meter Test Kit
-
- E-Series
- Electronics Water Meter
-
- CX
- Capacitive Electromagnetic Flowsensor
-
- VN
- Compact Electromagnetic Flow Sensor
-
- VNS
- Compact Electromagnetic Flow Sensors
-
- OF-Z
- Ovel gear Flow Sensor
-
- OF-WN / OF-WP
- Microstream Sensor
-
- ND
- Flow Sensor
-
- NW / NW-P
- Instantaneous Flow-rate/
Integrating Flow Volume Flowmeter
-
- NDV10
- Small-size Flowsensor
-
- TRA
- Ultrasonic Flow Meter for Liquid
-
- AGV
- Electromagnetic Flow Meters
for Agricultural Applications